Clamp On Ground Resistance Tester

Prominent & Leading Wholesaler from Raipur, we offer metravi - clamp on ground resistance tester cet 02, metravi - clamp on ground resistance tester cet 04, metravi - clamp on ground resistance tester cet 05, metravi - clamp on ground resistance tester cet 06, metravi - clamp on ground resistance tester cet 01b and metravi - clamp on ground resistance tester cet 04b.

METRAVI - Clamp On Ground Resistance Tester CET 02

Request Callback

₹ 19250 / Piece Get Latest Price

Product Brochure
Test MethodClamp On
Resistance Range0.01Ω to 1500Ω
Display TypeClamp Digital
Power SourceRechargeable
Earth Tester TypeClamp Type
Protection ClassCAT III

The Metravi CET series Clamp-on Ground Resistance Testers feature:

  • Self-test facility. No need to wait a long time to boot. Ready to use immediately after being switched on.
  • Breakthrough relay self-test mode, using the most advanced processing algorithms and digital integration technology, fully intelligent.
  • Handheld device, easy to carry. New design, panel operation with 6 buttons, better performance. Loud sound and light alarms; “beep—beep–beep –” alarm sound.
  • Improved interference signal recognition indicator. Improved anti-jamming capability and test stability. Data storage: 99 Units. Wider range: 0.01Ω-1500Ω.
  • Lower power consumption: Maximum operating current does not exceed 50mA. Are widely used for grounding resistance measurement in power, telecommunications, meteorology, oil fields, construction industries and electrical equipments.
  • In the measurement of a grounding system with loop current, it does not require breaking down the grounding wire and needs no auxiliary electrode.
  • Safe, fast and simple to use.
  • Can measure ground faults beyond the reach of traditional methods and can be applied in situations not in the range of traditional methods.
  • Can measure integrated value of the grounding body resistance and the grounding lead resistance.
  • Equipped with long jaws (for some models). Long jaws are particularly suitable for testing grounding with flat steel.

METRAVI - Clamp On Ground Resistance Tester CET 04

Request Callback

₹ 22950 / Piece Get Latest Price

Product Brochure
Test MethodClamp On
Resistance Range0.01Ω-1500Ω.
Display TypeClamp Digital
Power SourceBattery
Earth Tester TypeHandheld
Protection ClassCAT II
Max Test Voltage20 V AC

The Metravi CET series Clamp-on Ground Resistance Testers feature:

  • Self-test facility. No need to wait a long time to boot. Ready to use immediately after being switched on.
  • Breakthrough relay self-test mode, using the most advanced processing algorithms and digital integration technology, fully intelligent.
  • Handheld device, easy to carry. New design, panel operation with 6 buttons, better performance. Loud sound and light alarms; “beep—beep–beep –” alarm sound.
  • Improved interference signal recognition indicator. Improved anti-jamming capability and test stability. Data storage: 99 Units. Wider range: 0.01Ω-1500Ω.
  • Lower power consumption: Maximum operating current is from 0.0mA to 20A. Are widely used for grounding resistance measurement in power, telecommunications, meteorology, oil fields, construction industries and electrical equipments.
  • In the measurement of a grounding system with loop current, it does not require breaking down the grounding wire and needs no auxiliary electrode.
  • Safe, fast and simple to use.
  • Can measure ground faults beyond the reach of traditional methods and can be applied in situations not in the range of traditional methods.
  • Can measure integrated value of the grounding body resistance and the grounding lead resistance.
  • Also able to measure leakage current and neutral current in the grounding system.

METRAVI - Clamp On Ground Resistance Tester CET 05

Request Callback

₹ 18000 / Piece Get Latest Price

Product Brochure
Test MethodClamp On
Resistance Range0.01Ω-200Ω.
Display TypeClamp Digital
Power SourceBattery
Earth Tester TypeHandheld
Protection ClassCAT II

The Metravi CET series Clamp-on Ground Resistance Testers feature:

  • Self-test facility. No need to wait a long time to boot. Ready to use immediately after being switched on.
  • Breakthrough relay self-test mode, using the most advanced processing algorithms and digital integration technology, fully intelligent.
  • Handheld device, easy to carry. New design, panel operation with 6 buttons, better performance. Loud sound and light alarms; “beep—beep–beep –” alarm sound.
  • Improved interference signal recognition indicator. Improved anti-jamming capability and test stability. Data storage: 99 Units. Wider range: 0.01Ω-200Ω.
  • Lower power consumption: Maximum operating current does not exceed 50mA. Are widely used for grounding resistance measurement in power, telecommunications, meteorology, oil fields, construction industries and electrical equipments.
  • In the measurement of a grounding system with loop current, it does not require breaking down the grounding wire and needs no auxiliary electrode.
  • Safe, fast and simple to use.
  • Can measure ground faults beyond the reach of traditional methods and can be applied in situations not in the range of traditional methods.
  • Can measure integrated value of the grounding body resistance and the grounding lead resistance.
  • Equipped with long jaws (for some models). Long jaws are particularly suitable for testing grounding with flat steel.

METRAVI - Clamp On Ground Resistance Tester CET 06

Request Callback

₹ 18000 / Piece Get Latest Price

Product Brochure
Test MethodClamp On
Resistance Range0.01–200 Ω
Earth Tester TypeClamp Type
Power SourceBattery
Protection ClassCAT II
Display TypeDigital
IP RatingIP40

The Metravi CET series Clamp-on Ground Resistance Testers feature:

  • Self-test facility. No need to wait a long time to boot. Ready to use immediately after being switched on.
  • Breakthrough relay self-test mode, using the most advanced processing algorithms and digital integration technology, fully intelligent.
  • Handheld device, easy to carry. New design, panel operation with 6 buttons, better performance. Loud sound and light alarms; “beep—beep–beep –” alarm sound.
  • Improved interference signal recognition indicator. Improved anti-jamming capability and test stability. Data storage: 99 Units. Wider range: 0.01Ω-200Ω.
  • Lower power consumption: Maximum operating current does not exceed 50mA. Are widely used for grounding resistance measurement in power, telecommunications, meteorology, oil fields, construction industries and electrical equipments.
  • In the measurement of a grounding system with loop current, it does not require breaking down the grounding wire and needs no auxiliary electrode.
  • Safe, fast and simple to use.
  • Can measure ground faults beyond the reach of traditional methods and can be applied in situations not in the range of traditional methods.
  • Can measure integrated value of the grounding body resistance and the grounding lead resistance.

METRAVI - Clamp On Ground Resistance Tester CET 01B

Request Callback

₹ 19250 / Piece Get Latest Price

Product Brochure
Test Method3 Pole
Resistance Range0.01Ω-1500Ω
Earth Tester TypeClamp Type
Power SourceBattery
Protection ClassCAT III
Display TypeBacklit LCD
IP RatingIP40

The Metravi CET-01B Clamp-on Ground Resistance Tester with Bluetooth is widely used in earth resistance measurement and loop resistance measurement in electric power, telecommunications, meteorology, oil fields, construction and industrial electrical equipment.

When measuring the grounding system of the loop circuit, there is no need to disconnect the grounding down lead or auxiliary earth electrode, and it enables safe and fast testing.
The Metravi CET-01B Clamp-on Ground Resistance Tester with Bluetooth can measure ground faults that cannot be measured by traditional methods, and can be applied to the site which cannot be measured by traditional methods, as earth resistance tester measures the comprehensive value of the grounding body resistance and the grounding lead resistance.

Features:

  • Avoids long self-test waiting after power-on, and enters the test interface immediately after power-on.
  • No relay self-test and adopts advanced algorithms and digital integrated processing technology.
  • No bulky problem of old products and is portable & handheld.
  • New housing & design, six operation keys on the panel, easy to operate.
  • Added sound and light alarm function, will have “”beep–beep– beep–“” alarm sound.
  • Added interference signal identification and indication function, will have “”beep–beep–beep–“” prompt sound.
  • Measurement range 0.01Ω-1500Ω.
  • Stores 99 groups of data, has lower power consumption, maximum startup and operating current less than 50mA.
  • Bluetooth enabled and Free App for data storage and analysis.

METRAVI - Clamp On Ground Resistance Tester CET 04B

Request Callback

₹ 23780 / Piece Get Latest Price

Product Brochure
Test MethodClamp On
Resistance Range0.01Ω-1500Ω.
Ground Tester TypeClamp Type
Power SourceBattery
Display TypeDigital
Protection ClassCAT IV
Max Test Voltage20 V AC

The Metravi CET-04B Clamp-on Earth Resistance Tester is widely used in earth resistance measurement and loop resistance measurement in electric power, telecommunications, meteorology, oil fields, construction and industrial electrical equipment.

When measuring the grounding system of the loop circuit, there is no need to disconnect the grounding down lead or auxiliary earth electrode, and it enables safe and fast testing.
The tester can measure ground faults that cannot be measured by traditional methods, and can be applied to the site which cannot be measured by traditional methods, as earth resistance tester measures the comprehensive value of the grounding body resistance and the grounding lead resistance.

Metravi  CET-04B Clamp-on Earth Resistance Testers has a round jaw. It can also measure leakage current grounding system and the neutral current.

Features:

  • Avoids long self-test waiting after power-on, and enters the test interface immediately after power-on.
  • No relay self-test and adopts advanced algorithms and digital integrated processing technology.
  • No bulky problem of old products and is portable & handheld.
  • New housing & design, six operation keys on the panel, easy to operate.
  • Added sound and light alarm function, will have “”beep–beep– beep–“” alarm sound.
  • Added interference signal identification and indication function, will have “”beep–beep–beep–“” prompt sound.
  • Measurement range 0.01Ω-1500Ω.
  • Stores 99 groups of data, has lower power consumption, maximum startup and operating current less than 50mA.
  • Bluetooth enabled and Free App for data storage and analysis.

METRAVI - Clamp On Ground Resistance Tester CET 05B

Request Callback

₹ 18000 / Piece Get Latest Price

Product Brochure
Test MethodClamp On
Resistance Range0.01Ω – 200Ω.
Earth Tester TypeClamp Type
Power SourceBattery
Protection ClassCAT II
Display TypeDigital
InterfaceBluetooth

The Metravi CET-05B Clamp-on Earth Resistance Tester is widely used in earth resistance measurement and loop resistance measurement in electric power, telecommunications, meteorology, oil fields, construction and industrial electrical equipment.

When measuring the grounding system of the loop circuit, there is no need to disconnect the grounding down lead or auxiliary earth electrode, and it enables safe and fast testing.
The tester can measure ground faults that cannot be measured by traditional methods, and can be applied to the site which cannot be measured by traditional methods, as earth resistance tester measures the comprehensive value of the grounding body resistance and the grounding lead resistance.

Metravi CET-05B Clamp-on Earth Resistance Tester has a long jaw which is suitable for the site of flat steel grounding. It can also measure leakage current grounding system and the neutral current.

Features:

  • Avoids long self-test waiting after power-on, and enters the test interface immediately after power-on.
  • No relay self-test and adopts advanced algorithms and digital integrated processing technology.
  • No bulky problem of old products and is portable & handheld.
  • New housing & design, six operation keys on the panel, easy to operate.
  • Added sound and light alarm function, will have “”beep–beep– beep–“” alarm sound.
  • Added interference signal identification and indication function, will have “”beep–beep–beep–“” prompt sound.
  • Measurement range 0.01Ω – 200Ω.
  • Stores 99 groups of data, has lower power consumption, maximum startup and operating current less than 50mA.
  • Bluetooth enabled and Free App for data storage and analysis.

METRAVI - Clamp On Ground Resistance Tester CET 06B

Request Callback

₹ 22950 / Piece Get Latest Price

Product Brochure
Test MethodClamp On
Resistance Range0.01–2000 Ω
Earth Tester TypeClamp Type
Power SourceBattery
Protection ClassCAT III
Display TypeBacklit LCD
InterfaceBluetooth

The Metravi CET series Clamp-on Ground Resistance Testers feature:

  • Self-test facility. No need to wait a long time to boot. Ready to use immediately after being switched on.
  • Breakthrough relay self-test mode, using the most advanced processing algorithms and digital integration technology, fully intelligent.
  • Handheld device, easy to carry. New design, panel operation with 6 buttons, better performance. Loud sound and light alarms; “beep—beep–beep –” alarm sound.
  • Improved interference signal recognition indicator. Improved anti-jamming capability and test stability. Data storage: 99 Units. Wider range: 0.01Ω-200Ω.
  • Lower power consumption: Maximum operating current does not exceed 50mA. Are widely used for grounding resistance measurement in power, telecommunications, meteorology, oil fields, construction industries and electrical equipments.
  • In the measurement of a grounding system with loop current, it does not require breaking down the grounding wire and needs no auxiliary electrode.
  • Safe, fast and simple to use.
  • Can measure ground faults beyond the reach of traditional methods and can be applied in situations not in the range of traditional methods.
  • Can measure integrated value of the grounding body resistance and the grounding lead resistance.

METRAVI - Clamp On Ground Resistance Tester CET 05S

Request Callback

₹ 13500 / Piece Get Latest Price

Product Brochure
Test Method4 Pole
Resistance Range0.01–20 Ω
Earth Tester TypeHandheld
Display TypeDigital
Power SourceBattery
Protection ClassCAT II
IP RatingIP40
Max Test Voltage40 V AC

The Metravi CET-05S Clamp-on Earth and Ground Resistance Tester is widely used in earth resistance measurement and loop resistance measurement in electric power, telecommunications, meteorology, oil fields, construction and industrial electrical equipment.

When measuring the grounding system of the loop circuit, there is no need to disconnect the grounding down lead or auxiliary earth electrode, and it enables safe and fast testing. The tester can measure ground faults that cannot be measured by traditional methods, and can be applied to the site which cannot be measured by traditional methods, as earth resistance tester measures the comprehensive value of the grounding body resistance and the grounding lead resistance.

The Metravi CET-05S Clamp-on Earth and Ground Resistance Tester has the long jaw style, which is suitable for the site of flat steel grounding.

Features:

  • Avoids long self-test waiting after power-on, and enters the test interface immediately after power-on.
  • No relay self-test and adopts advanced algorithms and digital integrated processing technology.
  • No bulky problem of old products and is portable & handheld.
  • New housing & design, easy to operate.
  • Added sound and light alarm function, will have “”beep–beep–beep–“” alarm sound.
  • Added interference signal identification and indication function, will have “”beep–beep–beep–“” prompt sound.
  • Measurement range 0.01Ω-200Ω.

METRAVI - Clamp On Ground Resistance Tester CET 02B

Request Callback

₹ 19250 / Piece Get Latest Price

Test MethodClamp On
Resistance Range0.01Ω-1500Ω
Earth Tester TypeHandheld
Display TypeClamp Digital
Power SourceBattery
ModelCET-02B
Resistance Accuracy1%

The Metravi CET-02B Clamp-on Earth Resistance Tester is widely used in earth resistance measurement and loop resistance measurement in electric power, telecommunications, meteorology, oil fields, construction and industrial electrical equipment.

When measuring the grounding system of the loop circuit, there is no need to disconnect the grounding down lead or auxiliary earth electrode, and it enables safe and fast testing.
The tester can measure ground faults that cannot be measured by traditional methods, and can be applied to the site which cannot be measured by traditional methods, as earth resistance tester measures the comprehensive value of the grounding body resistance and the grounding lead resistance.

Metravi CET-02B Clamp-on Earth Resistance Tester has a long jaw which is suitable for the site of flat steel grounding.

Features:

  • Avoids long self-test waiting after power-on, and enters the test interface immediately after power-on.
  • No relay self-test and adopts advanced algorithms and digital integrated processing technology.
  • No bulky problem of old products and is portable & handheld.
  • New housing & design, six operation keys on the panel, easy to operate.
  • Added sound and light alarm function, will have “”beep–beep– beep–“” alarm sound.
  • Added interference signal identification and indication function, will have “”beep–beep–beep–“” prompt sound.
  • Measurement range 0.01Ω-1500Ω.
  • Stores 99 groups of data, has lower power consumption, maximum startup and operating current less than 50mA.
  • Bluetooth enabled and Free App for data storage and analysis.

METRAVI - Clamp On Ground Resistance Tester CET 03

Request Callback

₹ 22950 / Piece Get Latest Price

Product Brochure
Test Method3 Pole
Resistance Range0.01Ω to 1500Ω
Display TypeClamp Digital
Power SourceBattery
Earth Tester TypeClamp Type
Protection ClassCAT III

The Metravi CET series Clamp-on Ground Resistance Testers feature:

  • Self-test facility. No need to wait a long time to boot. Ready to use immediately after being switched on.
  • Breakthrough relay self-test mode, using the most advanced processing algorithms and digital integration technology, fully intelligent.
  • Handheld device, easy to carry. New design, panel operation with 6 buttons, better performance. Loud sound and light alarms; “beep—beep–beep –” alarm sound.
  • Improved interference signal recognition indicator. Improved anti-jamming capability and test stability. Data storage: 99 Units. Wider range: 0.01Ω-1500Ω.
  • Lower power consumption: Maximum operating current is from 0.0mA to 30A. Are widely used for grounding resistance measurement in power, telecommunications, meteorology, oil fields, construction industries and electrical equipments.
  • In the measurement of a grounding system with loop current, it does not require breaking down the grounding wire and needs no auxiliary electrode.
  • Safe, fast and simple to use.
  • Can measure ground faults beyond the reach of traditional methods and can be applied in situations not in the range of traditional methods.
  • Can measure integrated value of the grounding body resistance and the grounding lead resistance.
  • Equipped with long jaws (for some models). Long jaws are particularly suitable for testing grounding with flat steel.
  • Also able to measure leakage current and neutral current in the grounding system.

METRAVI - Clamp On Ground Resistance Tester CET 02 EX

Request Callback

₹ 33600 / Piece Get Latest Price

Product Brochure
Test MethodClamp On
Resistance Range0.01Ω to 1200Ω
Ground Tester TypeClamp Type
Display TypeClamp Digital
Power SourceBattery
Protection ClassCAT III

The Metravi CET-02EX is an Explosion-proof Clamp-On Ground Resistance Tester with a 32 X 65 mm Clamp Jaw.

The CET-02EX has passed the explosion-proof certification and is cleared for GB3836-2000 explosive gas environment with electrical equipment. The explosion-proof marks is Exia Ⅱ BT3Ga. Explosion-proof qualified number: CE18.2380.
It can be applied to corresponding inflammable and explosive environment.

It features:

1. Measurement of Earth Resistance and Loop Resistance

2. Resistance Measurement Range: 0.010Ω~1200Ω

3. Data Storage: 99 sets

4. Alarm Threshold Setting:1-199Ω

5. Audible and Visual Alarms

METRAVI - Clamp On Ground Resistance Tester CET 09

Request Callback

₹ 49200 / Piece Get Latest Price

Product Brochure
Test Method4 Pole
Resistance Range0.01Ω to 1500Ω
Ground Tester TypeClamp Type
Power SourceBattery
Display TypeDigital
Protection ClassCAT III

Clamp-on Ground Resistance Tester with USB Interface and Rechargeable Battery.

The Metravi CET-09 features Ground Resistance, Loop Resistance, Leakage Current measurements as well as judges Ground Faults. With USB communication interface, stored data can be uploaded to the computer, and through software analysis, reports can be printed or shared. It can measure up to 40A leakage current.

Real-time clock function displays present time, and it supports multi-parameter on-screen display function – displaying grounding resistance and ground leakage current at the same time, which makes measurements practical, convenient and efficient.

METRAVI - Clamp On Ground Resistance Tester CET 05AS

Request Callback

₹ 19250 / Piece Get Latest Price

Product Brochure
Test Method4 Pole
Resistance Range0.01–200 Ω
Display TypeClamp Digital
Power SourceBattery
Earth Tester TypeHandheld
Protection ClassCAT III

The Metravi CET-05S Clamp-on Earth and Ground Resistance Tester is widely used in earth resistance measurement and loop resistance measurement in electric power, telecommunications, meteorology, oil fields, construction and industrial electrical equipment.

When measuring the grounding system of the loop circuit, there is no need to disconnect the grounding down lead or auxiliary earth electrode, and it enables safe and fast testing. The tester can measure ground faults that cannot be measured by traditional methods, and can be applied to the site which cannot be measured by traditional methods, as earth resistance tester measures the comprehensive value of the grounding body resistance and the grounding lead resistance.

The Metravi CET-05S Clamp-on Earth and Ground Resistance Tester has the long jaw style, which is suitable for the site of flat steel grounding.

Features:

  • Avoids long self-test waiting after power-on, and enters the test interface immediately after power-on.
  • No relay self-test and adopts advanced algorithms and digital integrated processing technology.
  • No bulky problem of old products and is portable & handheld.
  • New housing & design, easy to operate.
  • Added sound and light alarm function, will have “”beep–beep–beep–“” alarm sound.
  • Added interference signal identification and indication function, will have “”beep–beep–beep–“” prompt sound.
  • Measurement range 0.01Ω-200Ω.

METRAVI - Clamp On Ground Resistance Tester CET 01

Request Callback

₹ 19250 / Piece Get Latest Price

Product Brochure
Test MethodClamp On
Resistance Range0.01Ω to 1500Ω
Display TypeBacklit LCD
Earth Tester TypeClamp Type
Power SourceBattery
Protection ClassCAT II

The Metravi CET series Clamp-on Ground Resistance Testers feature:

  • Self-test facility. No need to wait a long time to boot. Ready to use immediately after being switched on.
  • Breakthrough relay self-test mode, using the most advanced processing algorithms and digital integration technology, fully intelligent.
  • Handheld device, easy to carry. New design, panel operation with 6 buttons, better performance. Loud sound and light alarms; “beep—beep–beep –” alarm sound.
  • Improved interference signal recognition indicator. Improved anti-jamming capability and test stability. Data storage: 99 Units. Wider range: 0.01Ω-1500Ω.
  • Lower power consumption: Maximum operating current does not exceed 50mA. Are widely used for grounding resistance measurement in power, telecommunications, meteorology, oil fields, construction industries and electrical equipments.
  • In the measurement of a grounding system with loop current, it does not require breaking down the grounding wire and needs no auxiliary electrode.
  • Safe, fast and simple to use.
  • Can measure ground faults beyond the reach of traditional methods and can be applied in situations not in the range of traditional methods.
  • Can measure integrated value of the grounding body resistance and the grounding lead resistance.

METRAVI - Clamp On Ground Resistance Tester CET 03B

Request Callback

₹ 23780 / Piece Get Latest Price

Test MethodClamp On
Resistance Range0.01-1500
Display TypeDigital
Power SourceBattery
Earth Tester TypeHandheld
InterfaceBluetooth

The Metravi CET-03B Clamp-on Earth and Ground Resistance Tester with Bluetooth is widely used in earth resistance measurement and loop resistance measurement in electric power, telecommunications, meteorology, oil fields, construction and industrial electrical equipment.

When measuring the grounding system of the loop circuit, there is no need to disconnect the grounding down lead or auxiliary earth electrode, and it enables safe and fast testing.
The tester can measure ground faults that cannot be measured by traditional methods, and can be applied to the site which cannot be measured by traditional methods, as earth resistance tester measures the comprehensive value of the grounding body resistance and the grounding lead resistance.

The Metravi CET-03B Clamp-on Earth and Ground Resistance Tester with Bluetooth has a long jaw which is suitable for the site of flat steel grounding. It can also measure leakage current grounding system and the neutral current.

Features:

  • Avoids long self-test waiting after power-on, and enters the test interface immediately after power-on.
  • No relay self-test and adopts advanced algorithms and digital integrated processing technology.
  • No bulky problem of old products and is portable & handheld.
  • New housing & design, six operation keys on the panel, easy to operate.
  • Added sound and light alarm function, will have “”beep–beep– beep–“” alarm sound.
  • Added interference signal identification and indication function, will have “”beep–beep–beep–“” prompt sound.
  • Measurement range 0.01Ω-1500Ω.
  • Stores 99 groups of data, has lower power consumption, maximum startup and operating current less than 50mA.
  • Bluetooth enabled and Free App for data storage and analysis.
X

Contact Us

Nirmal Bengani (CEO)
Galaxy International
B 25 M G ROAD
Raipur - 492001, Chhattisgarh, India

Get Directions
Send Email
Share: